Specifications:
- treatedwith MPL
- thickness at 0.025 MPa: 172,9 µm
- thickness at 2 MPa: 134,1 µm
- area weight (DIN EN ISO 29073-1): 89 g/m²
- compression set at 2 MPa: 3,1 μm
- TP resistance at 2 MPa 2-Point: 3,4 mΩ·cm²
- IP resistance (cd 4-Point): 3,24 Ω
- IP resistance (md 4-Point): 2,77 Ω
- TP air permeability [1,22 kPa – 100 ml – 6,42 cm²]: 0,5 s
- size: A4, 21 x 30 cm